Skip to content Skip to navigation menu

Electrode

Item #:13E200=60

Available Today
Log in to order
Suggested HCPCS Coding: Included in base code
Use L7510 for replacement
Learn more at Reimbursement Services

Four times more powerful than older electrodes, the 13E200 Myobock Electrode lessens sensitivity to low and high frequency interferences as well as provides noise filtration.  Made of pure titanium, they are suitable for people with allergies.

As the industry standard, 13E200 MyoBock Electrode provides:

  • Enhanced sensitivity in low muscle signal range and increased differential in high muscle signal range to broaden the spectrum of potential patients
  • Decreased sensitivity to low and high frequency interference assures prostheses operation is not interrupted
  • Titanium construction, making it suitable for patients with allergies
  • Drop-in replacement for 13E125=60 electrode
  • 13E200=* (50 or 60 HZ) Electrode
  • 13E153 Electrode Accessories

Article number 13E200=60 13E200=50
Weight 4.5 g 4.5 g
HZ 60 50
Operating voltage 4.8 - 7.2 V 4.8 - 7.2 V
Dimensions LxWxH 27 x 18 x 9.5 mm 27 x 18 x 9.5 mm
Frequency bandwidth 90 to 450 Hz 90 to 450 Hz
Ambient temperature -15 to +60 degrees C -15 to +60 degrees C
Compatible for use in North America Not for use In North America
BBHSMLSW-W

BB HAND S LH SW W

BBHMDLQD-U

BB HAND M LH EQD

757M11=X-CHANGE

MyoBoy

BBHLGLQD-F

BB HAND L LH F

BBHLGRSW-U

BB HAND L RH SW

8E38=8-R8 1/4

SensorHand Speed

BBHMDLQD-MF

BB HAND M LH MF

8E38=8-R7 1/4

SensorHand Speed

8E38=8-L7 3/4

SensorHand Speed

8E38=8-R7 3/4

SensorHand Speed

8E38=8-L8 1/4

SensorHand Speed

BBHMDRQD-F

BB HAND M RH F

BBHLGLSW-U

BB HAND L LH SW

BBHSMLQD-B-F

BB HAND S LH FLEX B

8E38=8-L7 1/4

SensorHand Speed

BBHLGRQD-F

BB HAND L RH F

BBHLGRQD-MF

BB HAND L RH MF

BBHMDRQD-U

BB HAND M RH EQD

BBHLGLQD-MF

BB HAND L LH MF

BBHMDLSW-U

BB HAND M LH SW

BBHMDRSW-U

BB HAND M RH SW

BBHMDRQD-MF

BB HAND M RH MF

BBHLGLQD-U

BB HAND L LH EQD

BBHSMRSW-B

BB HAND S RH SW B

BBHSMRQD-W-F

BB HAND S RH FLEX W

BBHSMLQD-W-F

BB HAND S LH FLEX W

BBHSMRSW-W

BB HAND S RH SW W

BBHSMLSW-B

BB HAND S LH SW B

8E39=8-R7 3/4

SensorHand Speed

8E39=8-L8 1/4

SensorHand Speed

8E39=8-L7 3/4

SensorHand Speed

BBHLGRQD-U

BB HAND L RH EQD

8E39=8-L7 1/4

SensorHand Speed

8E39=8-R8 1/4

SensorHand Speed

8E39=8-R7 1/4

SensorHand Speed

BBHSMRQD-B-F

BB HAND S RH FLEX B

BBHMDLQD-F

BB HAND M LH F

13E200 Electrode - Instructions for Use (qualified personnel)

Instructions for Use: 647H490 (EN/DE/FR/IT/ES/PT/NL/SV/DA/HU/CS/RO/TR/EL)

Published Date: May 23, 2016

MyoBock System Overview

Product Information: 646F277 (EN)

Published Date: January 1, 2013